D3 FastPointTM L-DFATM Influenza A/Influenza B Virus Identification Kit - Respiratory Testing Solutions

D3 FastPoint is a Revolutionary Technology that allows for the identification of Influenza A & B with DFA accuracy in under 25 minutes from specimen receipt to virus identification.

Accuracy Matters

D3 FastPoint™ gives you the accuracy and quality of DFA direct specimen testing in a rapid timeframe while confirming specimen adequacy by letting you visualize stained cells under the microscope. This avoids false negatives due to inadequate cell counts.

Speed Matters

D3 FastPoint provides accurate results in the same time frame as rapid antigen tests. This allows laboratories to report results within the critical care window without compromising quality.

Multiplex Format

D3 FastPoint’s fluorescent technology provides results by combining two fluorescent labeled antibodies in one reagent, allowing for identification of two viruses in one step. These fluorescent results can be read easily using a fluorescence microscope with a single filter set.

Please contact your sales representative for more information about the D3 FastPoint L-DFATM Respiratory Identification Kit.


Product Numbers

01-120001           D3 FastPoint L-DFA Influenza A/Influenza B Virus Identification Kit (50 Tests)
Includes: L-DFA Influenza A/Influenza B Reagent (4-mL), 40X PBS Concentrate (25-mL), Re-suspension Buffer (6-mL), Influenza A/Influenza B Virus Antigen Control Slides (5), L-DFA Influenza A/Influenza B Virus Specimen Slides & Coverslips (50)


 

Educational Resources

  • D3 Ultra Duet (now D3 FastPoint), a Novel Method for Direct Specimen Testing of Respiratory Viruses

    J Jollick, C Frech, J Klein, and B McCutchan, Diagnostic Hybrids, Athens, OH. Download File

  • Evaluation of D3 Ultra Duet (now D3 FastPoint) Liquid Preparation DFA as a Rapid Test for Respiratory Viruses from Direct Clinical Specimens

    R. Almond-Albro, H. Bonenfant, L. Leblanc and O. Perry. Dartmouth-Hitchcock Medical Center Virology Laboratory, Lebanon, NH. Download File

  • Evaluation of the Diagnostic Hybrids D3 Ultra Duet (now D3 FastPoint) Respiratory Virus Identification Kit for the Detection of Respiratory Viruses Directly from Clinical Specimens

    M Crowell and N Baalman, Saint Francis Hospital Virology Laboratory, Tulsa, OK. Download File

  • Liquid DFA? A Comparison of DFA Methods in the Detection of Respiratory Viruses in a Pediatric Tertiary Care Medical Center Located in the Intermountain West

    T Barney, R Grand-Pre, E Noordewier, A Phillips, M Dickey, EK Korgenski, and JA Daly. Department of Pathology, Division of Clinical Microbiology, Primary Children's Medical Center and University of Utah, Salt Lake City, UT. Download File